Re: Histamine kit

From: Anthony Bimbo (apbimbo@verizon.net)
Date: Tue Feb 26 2008 - 05:52:00 PST

  • Next message: S.Kumar: "Re: Histamine kit"

    Hello Marta:

    I sent the following out some time back so it might be of interest to you also.

     "Just came across this and thought it might be of interest to you in the Maldives. I've done several FAO /Ministry of Fisheries projects related to the Male Market fish waste so this test kit might be of interest. I have no commercial relationship with Neogen but do have interest in histamine testing as related to fishmeal and the raw materials used to produce high quality fishmeal."

    Newly approved histamine test for tuna

    Neogen Corporation has received approval from the AOAC Research Institute for its quantitative test for histamine that eliminates the need for the use of hazardous materials in the testing process, according to Neogen. Veratox for Histamine (AOAC-RI No. 070703) is a direct competitive ELISA test for the detection of histamine in fresh, canned or pouched tuna, packed in either oil or water. The test uses a uniquely simple water extraction process, and returns results in the range of 2.5 to 50 parts per million. The Veratox for Histamine AOAC validation studies showed a 95.4% recovery rate of spiked samples, when compared to the AOAC official fluorometric method, and no cross-reactivity to all other commonly occurring biogenic amines. www.neogen.com

    Regards

    Tony Bimbo
    Technical Consultant
    International Fisheries Technology
    55 Cedar Lane, PO Box 1606
    Kilmarnock, VA 22482 USA
    Tel /Fax 804-435-3915
    Email apbimbo@verizon.net
      ----- Original Message -----
      From: Marta Pagazaurtundua
      To: seafood@ucdavis.edu
      Sent: Tuesday, February 26, 2008 2:56 AM
      Subject: Histamine kit

      Hello!

       

      I'm looking for a Histamine test suitable for use on fishing vessels. It has to be very simple and easy to use. Does anybody know a kit for this purpose?

       

      Thank you very much.

       

      MARTA PAGAZAURTUNDUA
      DEPARTAMENTO CALIDAD
      SALICA, S.A.
      Polígono Industrial Landabaso, S/N
      48370 Bermeo - Bizkaia
      T : 94.6880500 - F : 94.6880376
      www.salica.es

       

      Este mensaje y los documentos que en su caso lleve anexos, pueden contener información confidencial y atañe exclusivamente a las personas a las que va dirigido. Cualquier opinión en él contenida es exclusiva de su autor y no representa necesariamente la opinión de Salica, S.A. Si usted no es el destinatario de este mensaje, considérese advertido de que lo ha recibido por error y que cualquier uso, difusión o copia están prohibidos legalmente. Si ha recibido este mensaje por error, le rogamos que nos lo comunique por la misma vía o al teléfono 94 6880500 y proceda a destruirlo inmediatamente.

       

      This email is confidential and intended solely for the use of the individual to whom it is addressed. Any views or opinions presented are solely those of the author and do not necessarily represent those of SALICA, S.A.. If you are not the intended recipient, be advised that you have received this email in error and that any use, dissemination, forwarding, printing, or copying of this email is strictly prohibited.
      If you have received this email in error please notify it to Salica by telephone on number + 34 94 6880500.

      La empresa Salica S.A. esta adscrita a la ley de protección de datos, con lo cual lleva a cabo todos los requisitos que esta ley requiere.

      Salica S.A. is adhered to Data Protection Law so fulfils all the requirements of the latter.



    This archive was generated by hypermail 2b29 : Tue Feb 26 2008 - 05:58:37 PST