RE: continuous monitoring

From: Rippen, Thomas E. (terippen@umes.edu)
Date: Wed Nov 01 2006 - 13:11:13 PST

  • Next message: Vikas Gupta: "RE: continuous temperature monitoring devices"

    Mike and Enrique,
     
    It really comes down to how short of a recording time interval will
    satisfy the "continuous" monitoring expectation of FDA. The agency
    generally accepts datalogging instrumentation which record at preset
    intervals (hopefully, appropriate for the process) and are not truly
    continuous. These devices would appear to remove the human element but
    a distinction should be made between continuous monitoring and
    continuous record-keeping. Even a cook recorded by an ink-on-paper
    continuous chart must be periodically monitored by the operator. If, by
    nature of the process, the smokehouse operator must check every five
    minutes to determine the end of cook (product endpoint temperature),
    then an argument can be made that any record verifying this activity, or
    even just the final endpoint temperature, should satisfy the
    record-keeping requirement of the HACCP regulation. The record must
    document that critical limits are met, or if not, that appropriate
    corrective actions are taken. Nothing in the regulation mandates the
    use of continuous record-keeping devices to satisfy this requirement.
    Someone from FDA, care to weigh in?
     
    Tom
     
    Thomas E. Rippen
    Seafood Technology Specialist
    Sea Grant Extension Program
    Center for Food Science and Technology
    University of Maryland Eastern Shore
    Princess Anne, MD 21853
    410-651-6636
    410-651-8498 fax
    terippen@umes.edu
    -----Original Message-----
    From: owner-seafood@ucdavis.edu [mailto:owner-seafood@ucdavis.edu] On
    Behalf Of Enrique Reinoso Pin
    Sent: Wednesday, November 01, 2006 2:42 PM
    To: Strang, Mike; HACCP mailing list (HACCP mailing list)
    Subject: Re: continuous monitoring
     
    Mike
    If you monitoring every time it is continuos. If you monitouring every 5
    minutes it is imtermitent.
    Enrique Reinoso
    enriquereinoso@hotmail.com
            ----- Original Message -----
            From: Strang, Mike <mailto:Mike.Strang@us.fjordseafood.com>
            To: HACCP mailing list (HACCP mailing list)
    <mailto:seafood@ucdavis.edu>
            Sent: Wednesday, November 01, 2006 2:11 PM
            Subject: continuous monitoring
             
            Another question concerning continuous temperature monitoring.
             
            We are monitoring internal fillet temperatures during a cook. We
    probe 3 of the thickest fillets with thermocouple probes, we read and
    record the fillet temperature every 5 minutes during the cook once all
    of the 3 fillets have reached the critical temperature.
             
            Why would this not be considered continuous monitoring?
             
             
             
            Mike Strang, QC Manager
            Ducktrap River of Maine
            57 Little River Drive
            Belfast, Maine 04915
            mike.strang@us.fjordseafood.com
            Ph: 800-508-7968
            Fax: 207-338-6288
             



    This archive was generated by hypermail 2b29 : Wed Nov 01 2006 - 13:15:19 PST